Table of Technical Parameters

https//www.racom.eu/eng/products/m/mg100/tech_param.html

Print version

4. Table of Technical Parameters

Tab. 4.1: Table of technical parameters

Frequency range
MG100x0 – module GPRS(obsolete, not in production)
MG100x1 – module GPRSQuad band GPRS (850, 900, 1800,1 900 MHz)
MG100x2 – module UMTS/HSDPA(obsolete, not in production)
MG100x3 – module UMTS/HSDPA(obsolete, not in production)
MG100x4 – module
UMTS/HSDPA/HSUPA
(obsolete, not in production)
Optional modules
slot 5ADIO (analog and digital inputs and outputs)
slot 4ethernet 10/100 Mbps
slot 32×RS232
slot 2reserved for connection of GPRS module
slot 1RS232 or galv. sep. RS232 or RS422/RS485
Antenna connectorFME – male
MTBF(Mean Time Between Failure)> 100 000 hours
Supply voltagetypically 13.8 V (10.8-15.6)
Power consumption MG100-GPRS
Receiving200–260 mA according to mounted modules
Transmitting260–320 mA according to mounted modules
Power consumption MG100-UMTS
Receiving200–260 mA according to mounted modules
Transmitting290–350 mA according to mounted modules
Consumption in SLEEP mode2.5 mA
Operating range of temperature−30 to +65 °C
Humidity5 to 95% non-condensing
Storage range of temperature−40 to +85 °C
Mechanical dimensions208×108×63 mm (71 mm – DIN rail including)
184×108×63 mm (short version)
Fasten holes spacing198×65 mm; ø 4.8 mm
Weight1.2 kg

Tab. 4.2: Standards complied

EMC (Electromagnetic Compatibility)ETSI EN 301 489-1
ETSI EN 301 489-7 GSM/GPRS
ETSI EN 301 489-24 UMTS
Electrical safetyCSN EN 60 950:2001
Wheeled vehicle usageUN Regulation No.10 (EHK No.10)

©  2024 RACOM s.r.o. All Rights Reserved.