Web interface

Print version

6. Web interface

RipEX2 can be easily managed from your computer using a web browser. If there is an IP connection between the computer and the respective RipEX2, you can simply enter the IP address of any RipEX2 in the network directly in the browser address line and log in. However, it is not recommended to manage an over-the-air connected RipEX2 in this way, because high amounts of data would have to be transferred over the Radio channel, resulting in quite long response times.

[Note]Note

Supported browser for desktop are: current versions of Edge, Chrome, Firefox and Safari and Internet Explorer v.11; for mobile equipment current versions of Safari for iOS and Chrome for Android.

When you need to manage an over-the-air connected RipEX2, log-in to a RipEX2, which your computer is connected to using either a cable (via LAN) or a high speed WAN (e.g. Internet). The RipEX2 which you are logged-in to in this way is called Local. Then you can manage any remote RipEX2 in the network over-the-air in a throughput-saving way: all the static data (e.g. Web page graphic objects) is downloaded from the Local RipEX2 and only information specific to the remote unit is transferred over the Radio channel. RipEX2 connected in such a way is called Remote.

When in Router mode, the IP address of either the Radio or Ethernet interface in the remote unit can be used for such a Remote management. IP routing between the source (IP of ETH interface in Local RipEX2) and the destination IP (either Radio or ETH interface in Remote RipEX2) existneeds to be configured properly.

When in Bridge mode, IP addresses of Ethernet interfaces are used for both the Local and Remote units. Be careful, each RipEX2 MUST have its unique IP address and all these IP addresses have to be within the same IP network (defined by the IP Mask) when Remote management is required in Bridge mode.

  • Login page

    The login page informs you about the Unit name and IP address of the RipEX2 unit you are trying to log in.

    The login page allows changing of the language of the whole web interface (English language is default).

    Web interface is designed for usage on all kinds of equipments – with different screen sizes and screen resolutions. Most of the pictures depicted in this User manual are taken on the desktop type of screen resolution.

  • Web page header

    The header of each web page contains:

    • Unit name and

    • IP address of the RipEX2 unit you are connected to

    • Identification of the web current page (2nd or 3rd level of the menu)

    • Remote access button

    • Changes to commit button

    • Refresh settings button

    • User menu button

6.1. Remote access

RipEX2 unit management is designed to work smoothly even when the unit under configuration is connected via relatively slow radio channel. In case of locally connected unit – direct configuration of the unit (accessing the unit IP address directly from the web browser) works fine. If the unit should be connected remotely via the radio network, the so-called “Remote access” needs to be used to configure and manage remote unit using bandwidth friendly volumes of transmitted data. Open the web browser, enter the IP address of a locally connected unit and connect to a remote radio (which needs to be accessible from the locally connected unit via the RipEX2 network).

Remote access can be activated via click on the Remote access button.

The connection to remote radio proceeds…

The IP address of the actually connected RipEX2 unit is displayed as part of the Remote access button. All the configuration settings are remotely available using standard web interface. Some of the Diagnostic features are available via local connection only.

6.2. Change to commit

All changes of configuration parameters are marked by different color.

Multiple configuration changes in various menus can be prepared prior to final Commit.

Changes to commit “basket” collects all the changes.

You can:

  • Apply (Save to radio unit) all the changes using Send Changes or

  • Discard all changes via Reset All

6.3. User menu

It is strongly recommended to change the default password.