Basic navigation | Local navigation

Support > MORSE system > Modules

Modules

Individual input and output modules are inserted into the motherboard (with a ColdFire processor 32 bit / 66 MHz, RAM 16 MB, FLASH 4 MB). This concept allows MORSE equipment (radio modems, GPRS modems and controllers) to be adapted to truly meet the needs of each individual application.

Note: MG100 - 2nd slot is always occupied for GSM module, only 1st, 3rd, 4th and 5th slots are available.

The following types of modules are available:

2x RS232

  • Two RS232 interfaces on a single module fully comply with the RS232 standard.
  • Each interface has a separate DSUB connector or terminals.
  • DSUB option - signals: RxD, TxD, RTS, CTS, DTR, DSR, RI, CD, GND.
  • Terminals option - signals: RxD, TxD, RTS, CTS, GND.
  • Can be mounted in the 3rd slot.

Ethernet

  • Fully-fledged Ethernet type interface is mounted with a standard RJ45/STP connector.
  • The module automatically sets communication to a speed of 10 or 100 Mbit/s according to the speed of the network it is connected to.
  • Can be mounted in the 4th slot.

GPS

  • 16 channel GPS receiver with accuracy to 2.5 m.
  • NMEA protocol output for connecting other devices.
  • Configurable time pulse output (1 ms to 60 sec).
  • One status digital input.
  • Can be mounted in the 1st or 2nd slot.

M-BUS

  • The M-BUS board serves as the MASTER interface of the physical layer of the M-BUS.
  • Number of SLAVE meters 1–5.
  • Galvanic separation.
  • Protection and indication of a short circuit on the bus.
  • Can be mounted in the 1st or 2nd slot.

I/O

  • The board of analog and digital inputs and outputs (ADIO module) is designed for creating 20 mA current loops.
  • I/O input module contains 2×Analog In, 2×Analog Out, 2×Digital In, 2×Digital Out.
  • Communication with the I/O board over protocol Modbus, IEC 870-5-2, DF1. Other protocols are implemented as required.
  • The module is mounted with disconnecting connectors with screw terminals.
  • A standard I/O module can be modified to order. A maximum of 5 bi-directional inputs/outputs and 3 outputs are available.
  • Can be mounted in the 5th slot.

1× RS232

  • Interface fully compliant with the RS232 standard..
  • DSUB option - signals: RxD, TxD, RTS, CTS, DTR, DSR, RI, CD, GND.
  • Terminals option - signals: RxD, TxD, RTS, CTS, GND.
  • Can be mounted in the 1st or 2nd slot.

1× RS232 optically isolated

  • Interface fully compliant with the RS232 standard with optical and galvanic isolation.
  • DSUB option - signals: RxD, TxD, RTS, CTS, DTR, DSR, RI, CD, GND.
  • Terminals option - signals: RxD, TxD, RTS, CTS, GND.
  • Can be mounted in the 1st or 2nd slot.

1× RS422/RS485 optical isolated

  • Interface fully compliant with the RS232 or RS485 standard with optical and galvanic isolation.
  • DSUB option - signals: RxD-, RxD+, TxD-, TxD+, GND.
  • Terminals option - signals: RxD-, RxD+, TxD-, TxD+, GND.
  • Can be mounted in the 1st or 2nd slot.
 