Table of Technical Parameters

https//www.racom.eu/eng/products/m/mw160/tech_param.html

Print version

4. Table of Technical Parameters

Tab. 4.1: Table of technical parameters MW160

Frequency rangeMW160: 135–175 MHz
Channel spacing200 kHz
Means of setting working frequencysoftware in range +3.2 MHz from base frequency
Switching time transmitting/receiving< 1.5 ms
Receiver sensitivity for BER 10-3better than -100 dBm
Software adjustable output power 1)0.1–5 W
0.1–25 W
Max. modulation rate for transmitting133 kbit/s in 200 kHz channel
Optional modules
slot 5ADIO (analog and digital inputs and outputs)
slot 4Ethernet 10/100 Mbps
slot 32×RS232
slot 2RS232 or galv. sep. RS232 or RS422/RS485
slot 1
Antenna connectorN
MTBF(Mean Time Between Failure)> 500.000 hours (> 50 years)
Supply nominal voltage13.8 V
Supply voltage range10.8–15.6 V
Idle consumption (Rx) 2)420 mA + modules: (Eth. 30 mA, ADIO 50 mA, SCC 5 mA)
Transmission consumption (Tx) 2)5.5 A / 25 W
Consumption in SLEEP mode2.5 mA
Operating range of temperature-25 to +55 °C
Storage range of temperature-40 to +85 °C
Mechanical dimensions208×108×63 mm (71 mm DIN rail including)
184×108×63 mm (short version)
Spacing of fastening holes198×65 mm, ø 4.8 mm
Weight1.3 kg

1) Availability of specific types and frequencies check here, please. Presently these types are under mass production.
2) Approximate values dependent on frequency and modem type.

Tab. 4.2: Standards complied

EMC (Electromagnetic Compatibility)ETSI EN 301 489-5 V 1.3.1
Electrical safetyCSN EN 60 950:2001
Wheeled vehicle usageUN Regulation No.10 (EHK No.10)

©  2024 RACOM s.r.o. All Rights Reserved.