Quick Start Guide

https//www.racom.eu/eng/products/m/ray17/quick.html

Print version

Quick Start Guide

  • The default addresses of the RAy unit are 192.168.169.169/24 and 192.168.169.170/24.

  • On your PC set up a similar address with the same mask, e.g. 192.168.169.180/24.

    • To configure your PC’s address in Windows XP do the following: Start – Settings – Network Connections:
      Change properties of this connection – Internet Network Protocol (TCP/IP) – Properties – Use the following IP address – input 192.168.169.180 and use the mask 255.255.255.0. Click OK twice.

  • Connect both RAy units to a PoE source and connect to a PC via PoE for configuration, see Fig. Link Configuration.

  • Input the address of the connected RAy unit into the address field of your internet browser (such as Mozilla Firefox), e.g. 198.168.169.169. Login as admin with password admin.

  • Status menu provides information on connection.

  • Settings – Radio menu enables you to change the parameters of the radio and ethernet channel, Settings – Service Access – Users menu lets you change login parameters.

  • Continue as suggested by the Step-by-step Guide.

Link Configuration

Fig. 1: Link Configuration

©  2024 RACOM s.r.o. All Rights Reserved.