Misc – supplementary functions

https//www.racom.eu/eng/support/firmware/mr25/misc.html

Print version

15. Misc – supplementary functions

The menu (m)isc contains some auxiliary and service functions.

In the MORSE main menu type m Enter

Miscellaneous stuff:
(p)rotocol services
(t)ests
p(o)wer save po(w)er cycle
(b)att
(p)rotocol services

— the supplementary functions for some protocols (Skao, Modbus-Skao, GPS, Modbus), they are used according to the description for respective protocol

(t)ests

— the special tests used by some protocols, see the protocol description

p(o)wer save

— switching of CU (MR400 only) into sleep mode with minimal energy consumption

— switching of CU (MR400 only) into sleep mode with minimal energy consumption, see Section 3, “Power saving (SLEEP MODE)???TITLE???” in Communication unit chapter.

(b)att

— indicates the supply state. In MR25 modems it compares the supply voltage with the value (U)cc limit in the Communication unit menu. If the supply voltage is less than the (U)cc limit then the state is evaluated as the battery supply. The change is only indicated if it lasts for at least 60sec. Choose the function(b)att :

Batt

>>Power supply: OL. — OL indicates the network supplying. The report Error No 1051 is generated when passing to this state and saved in Event log as SUPPLY BACK EVT 1051

>>Power supply: OB. — OB indicates the battery supplying. The report Error No 1050 is generated when passing to this state and saved in Event log as SUPPLY DROP EVT 1050

(b)att

— indicates the supply state, which is the state of the input clamp PI in MR400 modems. This clamp is connected to the clamp MAIN PWR OFF on power supply MS2000. The explicit information is got here if the CU supplying is done from power network or from battery. Choose the function (b)att :

Batt

>>Power supply: OL.— OL indicates the network supplying. The report Error No 1051 is generated when passing to this state and saved in Event log as SUPPLY BACK EVT 1051

>>Power supply: OB. — OB indicates the battery supplying. The report Error No 1050 is generated when passing to this state and saved in Event log as SUPPLY DROP EVT 1050