Events

https//www.racom.eu/eng/support/firmware/mr400/events.html

Print version

20. Events

There is one central Event log in an CU. When an outstanding event is detected, a standard event record is generated. The second part of this menu item e(r)ror is designated for obsolete error log versions.

From MORSE main menu type i E Enter.

Event log pages
(0) (1) (2) (3)...(F)
(c)lear forma(t) ckh(k) (s)tatus
(q)uit
>>

Meaning of items:

(c)lear

— clears all events

forma(t)

— formats the memory space and clears all events Both (c) and (t) commands are reserved for special situations and should not be used during normal maintenance operations

ckh(k) (s)tatus

— for service purposes

(0) (1) ...

— pages of Event list, the latest event record can be found at the top of page (0)

type (0) Enter

>>
Event log name0 
2005-09-14 05:19:26| COLD START EVT 2000,00000044,02D10000
2005-09-14 05:19:15| PS SHUTDWN EVT 1999,00000000,00000000
2005-09-14 05:17:08| A:565098BA  test
2005-09-14 05:16:16| A:565098BA  put   MON SCC 3 O.K.
2005-09-14 05:16:16| A:565098BA  put   MON SCC 2 O.K.
2005-09-14 05:16:16| A:565098BA  put   MON SCC 1 O.K.
2005-09-14 05:16:16| A:565098BA  put   MON SCC 0 O.K.
2005-09-14 05:13:00| A:565098C6  put   UNIT 0 O.K.
2005-09-14 05:12:27| SUPPLY BACK EVT 1051,00000000,00000000
2005-09-14 05:11:47| SUPPLY DROP EVT 1050,00000001,00000000
2005-09-14 05:11:38| A:565098BA  write NODE 4 O.K.
2005-09-14 05:11:38| A:565098BA  write NODE 3 O.K.
2005-09-14 05:11:38| A:565098BA  write NODE 2 O.K.
2005-09-14 05:11:38| A:565098BA  write NODE 1 O.K.
2005-09-14 05:11:38| A:565098BA  write NODE 0 O.K.

The first part is the time when the event was detected, the second is a short description of it. The events recorded in example, chronologically from below:

A:565098BA write NODE 0 O.K.

— 5 configuration structures written by command write

SUPPLY DROP EVT 1050

— change the supply to accumulator, MR400 detect this state from hw signal PI lead from the clamp MAIN PWR OFF on supply MS2000, MR25 from parameters in the menu Unit

SUPPLY BACK EVT 1051

— turning back to power box

A:565098C6 put UNIT 0 O.K.

— writing Unit edit by Init command done from the remote CU having address 565098C6

A:565098BA put MON SCC 0 O.K.

— writing in iMSPe menu by Init command

A:565098BA test

— control some of tests by command start, stop or report

PS SHUTDWN EVT 1999

— switching OFF the supply

COLD START EVT 2000

— switching ON the supply