There is one central Event log in an CU. When an outstanding event is detected, a standard event record is generated. The second part of this menu item e(r)ror is designated for obsolete error log versions.
From MORSE main menu type i E Enter.
Event log pages (0) (1) (2) (3)...(F) (c)lear forma(t) ckh(k) (s)tatus (q)uit >>
Meaning of items:
(c)lear | — clears all events |
forma(t) | — formats the memory space and clears all events Both
|
ckh(k) (s)tatus | — for service purposes |
(0) (1) ... | — pages of Event list, the latest event record can be found at
the top of page |
type (0) Enter
>> Event log name0 2005-09-14 05:19:26| COLD START EVT 2000,00000044,02D10000 2005-09-14 05:19:15| PS SHUTDWN EVT 1999,00000000,00000000 2005-09-14 05:17:08| A:565098BA test 2005-09-14 05:16:16| A:565098BA put MON SCC 3 O.K. 2005-09-14 05:16:16| A:565098BA put MON SCC 2 O.K. 2005-09-14 05:16:16| A:565098BA put MON SCC 1 O.K. 2005-09-14 05:16:16| A:565098BA put MON SCC 0 O.K. 2005-09-14 05:13:00| A:565098C6 put UNIT 0 O.K. 2005-09-14 05:12:27| SUPPLY BACK EVT 1051,00000000,00000000 2005-09-14 05:11:47| SUPPLY DROP EVT 1050,00000001,00000000 2005-09-14 05:11:38| A:565098BA write NODE 4 O.K. 2005-09-14 05:11:38| A:565098BA write NODE 3 O.K. 2005-09-14 05:11:38| A:565098BA write NODE 2 O.K. 2005-09-14 05:11:38| A:565098BA write NODE 1 O.K. 2005-09-14 05:11:38| A:565098BA write NODE 0 O.K.
The first part is the time when the event was detected, the second is a short description of it. The events recorded in example, chronologically from below:
A:565098BA write NODE 0 O.K. | — 5 configuration structures written by command write |
SUPPLY DROP EVT 1050 | — change the supply to accumulator, MR400 detect this state from hw signal PI lead from the clamp MAIN PWR OFF on supply MS2000, MR25 from parameters in the menu Unit |
SUPPLY BACK EVT 1051 | — turning back to power box |
A:565098C6 put UNIT 0 O.K. | — writing Unit edit by Init command done from the remote CU having address 565098C6 |
A:565098BA put MON SCC 0 O.K. | — writing in iMSPe menu by Init command |
A:565098BA test | — control some of tests by command start, stop or report |
PS SHUTDWN EVT 1999 | — switching OFF the supply |
COLD START EVT 2000 | — switching ON the supply |