Basic navigation | Local navigation

GPRS modem
MG100

GPRS modem MG100

MG100 allows a hybrid network to be created in the MORSE system and where necessary allows the radio network to be supplemented by transmission via GPRS. MG100 is fully compatible with radio modems on user interfaces and is controlled using the same software tools.

Typical areas of use

  • Complements the MORSE network in places where it is uneconomical to build radio coverage and GSM coverage is already available there
  • For network points, where there is no emphasis placed on a guaranteed response time
  • For network points, which communicate infrequently (several times a day)
  • For network points, where potential GSM network failures are not critical
  • For supplementing the MORSE network with a point through which it is possible to perform remote supervision, servicing, and diagnostics of radio modems (in places where other remote access is not possible, e.g. via Internet)

Benefits

  • User compatible with radio modems
  • Dynamic and static IP addresses
  • Sleep mode with power consumption 2.5 mA
  • Modular concept - Ethernet, RS232 max 3x, RS422/485, GPS, M-BUS, I/O - 2xAI, 2xAO, 2xDI, 2xDO
  • High mechanical resistance - rugged die cast aluminum case
  • Assembly on DIN rails or using 4 × M4 screws
  • Programs for remote control, set-up, and diagnostics provided free of charge
  • Functionality proven in extreme climatic conditions in various parts of the world

Control and diagnostics Modules Operating manual Production code

Leaflet

Technical parameters

Frequency rangeGSM band 900 MHz, 1 800 MHz
Optional modules4 slots
Antenna connectorFME-male
MTBF (mean time between failures)> 100 000 hours
Power supply typically13.8 V (10.8–15.6)
Idle consumption (Rx)200 mA (eth +30 mA, I/O +50 mA, GPS +15 mA, SCC +5 mA)
Consumption during transmission (Tx)< 350 mA
Consumption in SLEEP mode2.5 mA
Operating temperatures range-25 to +55 °C
Storage temperature range-35 to +85 °C
Case dimensions208 × 108 × 63 mm
Weight1.2 kg
Standards complied
   EMC (electromagnetic compatibility)ETSI EN301489-5 V 1.3.10
   Electrical safetyCENELEC EN 60950:2000
   Use in mobile environmentsUN Regulation No.10 (EHK No.10)
 

www.racom.eu

RACOM, Mirova 1283, 592 31 Nove Mesto na Morave, Czech Republic, Tel.: +420 565 659 511, Fax: +420 565 659 512, E-mail: racom@racom.eu